{"created":"2023-05-15T11:18:44.802274+00:00","id":113,"links":{},"metadata":{"_buckets":{"deposit":"51e0d52f-bd63-402b-8e1f-fb3f63d279d3"},"_deposit":{"created_by":3,"id":"113","owners":[3],"pid":{"revision_id":0,"type":"depid","value":"113"},"status":"published"},"_oai":{"id":"oai:metro-cit.repo.nii.ac.jp:00000113","sets":["1:14:19"]},"author_link":["1053","1049","1051"],"item_1_biblio_info_14":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2011-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"46","bibliographicPageStart":"42","bibliographicVolumeNumber":"5","bibliographic_titles":[{"bibliographic_title":"東京都立産業技術高等専門学校研究紀要"},{"bibliographic_title":"Research reports of Tokyo Metropolitan College of Industrial Technology","bibliographic_titleLang":"en"}]}]},"item_1_creator_6":{"attribute_name":"著者名(日)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"福田, 恵子"},{"creatorName":"フクダ, ケイコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{}]}]},"item_1_creator_7":{"attribute_name":"著者名よみ","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"フクダ, ケイコ"}],"nameIdentifiers":[{}]}]},"item_1_creator_8":{"attribute_name":"著者名(英)","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Fukuda, Keiko","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_1_description_1":{"attribute_name":"ページ属性","attribute_value_mlt":[{"subitem_description":"P(論文)","subitem_description_type":"Other"}]},"item_1_description_12":{"attribute_name":"抄録(英)","attribute_value_mlt":[{"subitem_description":"Measurement of small analog signal is indispensable for various instrumentations especially inbiomedical measurements. Phase detection system is one of the most widely used ways for measuring small analogsignal in relatively low frequency signals. To understand the principle of such measurement system, visual andexperimental instructions are helpful. Thus, I proposed an exercise style learning method for phase detectionsystem by using Microsoft Excel. The phase detection system is modeled by the conventional functions used inMicrosoft Excel. The students practiced on studying the fundamental characteristics of the phase detection systemand the influence of the white noise on the system during computer exercise lessens. From the reports and thequestionnaire survey to evaluate the exercise style learning, it is confirmed that the proposed exercise stylelearning method is valuable for learning the principle, effectiveness and applications of the phase detection system.Further, it is effective for learning the usage of some functions of Microsoft Excel. This shows that the exercisestyle learning method with widely used conventional software has effect with relatively short time practices.","subitem_description_type":"Other"}]},"item_1_source_id_13":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA12210629","subitem_source_identifier_type":"NCID"}]},"item_1_text_9":{"attribute_name":"著者所属(日)","attribute_value_mlt":[{"subitem_text_value":"東京都立産業技術高等専門学校 ものづくり工学科医療福祉工学コース"}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2011-03-01"}],"displaytype":"detail","filename":"KJ00008921659.pdf","filesize":[{"value":"85.3 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"KJ00008921659","url":"https://metro-cit.repo.nii.ac.jp/record/113/files/KJ00008921659.pdf"},"version_id":"4a98d684-6f1e-461a-923e-ae719d969927"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Analog signal measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Biomedical measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Phase detection","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Synchronized detection","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Microsoft Excel","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Exercise style learning","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"エクセルを用いた位相検波方式の学習法とその効果","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"エクセルを用いた位相検波方式の学習法とその効果"},{"subitem_title":"Evaluation of Exercise Style Learning Method for Phase Detection System with Using","subitem_title_language":"en"}]},"item_type_id":"1","owner":"3","path":["19"],"pubdate":{"attribute_name":"公開日","attribute_value":"2011-03-01"},"publish_date":"2011-03-01","publish_status":"0","recid":"113","relation_version_is_last":true,"title":["エクセルを用いた位相検波方式の学習法とその効果"],"weko_creator_id":"3","weko_shared_id":3},"updated":"2023-05-15T11:31:51.316148+00:00"}